Tom,

Gates had a commercial amplifier (MODEL ST-3A) with 2nd harmonics down 50 db 
and all higher order down at least 60 db.  The input was 100 mw and the tube 
line up was: a 6CL6 in class A, an 8122 in class A and a 4CX3000A in AB1. 
The output was rated at 3000 watts.

73,
Ken W2DTC



______________________________________
Ken Barber  Middletown, NJ
Radio Website: http://w2dtc.com
_______________________________________


----- Original Message ----- 
From: "Tom Cathey" <K1JJ@comcast.net>
To: <amps@contesting.com>
Sent: Wednesday, December 14, 2005 12:49 PM
Subject: [Amps] Designing the Cleanest Linear with RF Negative Feedback


> Hi All,
>
> I'm planning to build up a 75M monoband amplifier that has at least -45db
> to -50db 3rd order IMD using heavy RF negative feedback. 10MW in, 1500W 
> out.
>
> I wanted to get opinions here what others thought was the best general
> configuration and perhaps suggest some real world tubes.
>
> It seems that the best amps that use RF feedback start with a much larger
> tube than generally used in open loop linears and run it about half power 
> .
>
> I plan to use the 10 milliwatt output from my FT-1000D as a source. This 
> is
> the low level stage just before it goes into the power amp board. I'm 
> hoping
> this is class A stuff and a  much cleaner starting point than its -32db 
> IMD
> 200W solid state power amplifier board output. Any opinions on that?
>
> For this amplifier I am thinking of either a chain of grounded grid stages
> so that they have individual built in feedback and an additional loop of
> feedback around the whole chain.
>
> OR, use a tetrode final with regulated screen voltage with stages going 
> back
> to amplify the 10MW level. Hopefully, use up to 15-20db of  loop feedback
> assuming the gain is available.
>
> I would appreciate any pointers to URLs showing working schematics of the
> big commerical amps that Collins, Harris, etc use, and ideas you may have
> for a design.
>
> For example... I don't know what good low level tubes to use, but lets 
> just
> say it went something like,  6AU6, 12BY7, 6146, 811A, 3-500Z,  GS-35B  - 
> all
> in grounded grid with an additional feedback loop.
>
> Or, for grid driven:  The same low level stages, then 4CX-150, 4-1000A,
> 4CX-3000.  Looking for conservative ratings at 1500W and high IMD figures.
>
> Another thing I wonder about is if a tube like the 6146 or 4-1000A which 
> has
> modest IMD figures open looped,  can successfully participate in a -45
> to -50db IMD chain when big feedback is used?
>
> I will be building this amp over the next few months and will post the
> results once completed. Thanks in advance for any help!
>
> 73,
> Tom, K1JJ
>
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps 

_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

<Prev in Thread] Current Thread [Next in Thread>