| To: | "robert briggs" <vk3zl@bigpond.com> |
|---|---|
| Subject: | Re: [Amps] 4CX1500B |
| From: | R.Measures <r@somis.org> |
| Date: | Thu, 22 Sep 2005 07:22:07 -0700 |
| List-post: | <mailto:amps@contesting.com> |
On Sep 21, 2005, at 3:28 PM, robert briggs wrote:
> I have received several query's about the Super Cathode Drive method
> on my 4CX250 B amplifiers.
> The amplifier's take around 100 watts of drive power for 600 watts
> output.
> When the drive input is correctly matched the Grid ("screen" ) current
> is 1 to 3 Ma with the amplifier loaded.Anode voltage 2500 vdc.
> Idle current for a pair of tubes is 25 to 30 Ma.
> According to Orr in his note's "QST July 1967 IMD 3rd order would be
> -46 db 5th order
> 49 db.I have no measuring equipment to confirm this.
The main tool needed to measure total IMD is a second SSB receiver --
preferably one with a double-filter -- tuned c. 4KHz above or below the
signal being measured.
> The point I am trying to establish is whether this setup would be
> applicable to the 4CX1500B.
The 4cx1500B already has low IMD in grid-driven config.
> Bob VK3ZL..
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
>
>
Richard L. Measures, AG6K, 805.386.3734. www.somis.org
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|
| <Prev in Thread] | Current Thread | [Next in Thread> |
|---|---|---|
| ||
| Previous by Date: | Re: [Amps] Ameritron 811H, R . Measures |
|---|---|
| Next by Date: | Re: [Amps] 4CX1500B, Carcia, Francis A HS |
| Previous by Thread: | [Amps] 4CX1500B, robert briggs |
| Next by Thread: | Re: [Amps] 4CX1500B, R . Measures |