In a message dated 09/01/2005 23:05:35 GMT Standard Time,  
G3SEK@ifwtech.co.uk writes:

The  minimum possible *loaded* Q that is required to transform between 
two  resistances R2>R1, using any possible circuit, is sqrt(R2/R1  -1).



Perfectly true if you don't use a transformer. The link coupled tuend  
circuit is a tuend transformer, and the impedance ratio is determined by the  
turns 
ratio. The Q is determined by the ratio of inductive reactance to the load  
impedance.
 
Going away shortlt, so may not be able to read e mail for some weeks.
 