I use a Ledex driving a ceramic rotary switch, the one about an inch and a  
quarter across. It has front and back contacts connected together, and 50 ohm  
strip lines from it to the 12 SO239 sockets. The SWR on 10meters is below 
1.1:1,  which is more than good enough, and it doesn't complain about carrying 
1kW 
- I  would never attempt switching that much.
 
It's mounted on the lid of a die cast box, with the Ledex outside, and has  
worked well (touching wood!) for over 10 years. The whole thing is in  an 
outside shed, so it isn't an ideal environment, but the switch wiping action  
helps.
 