Wondering if anyone has used a zero crossing circuit on a high voltage
supply to reduce inrush current at startup? would this work for soft start
or would it just assist?
Ed N5BLZ
Zero crossing circuits (solid-state relays) are far too fast acting for use as a soft-start device, Ed.

A properly designed soft-start circuit has a delay equal to the time it takes the H.V. meter to reach 2/3 of the way to its normal reading.

This varies with the size of the filter caps in the P.S. ; c. 1-3 seconds. Max. delay on a zero-crossing S.S. relay is many times less than needed.

(((73)))