Subject: [Amps] Zero Crossing circuitWondering if anyone has used a zero crossing circuit on a high voltageZero crossing circuits (solid-state relays) are far too fast acting for use as a soft-start device, Ed. A properly designed soft-start circuit has a delay equal to the time it takes the H.V. meter to reach 2/3 of the way to its normal reading. This varies with the size of the filter caps in the P.S. ; c. 1-3 seconds. Max. delay on a zero-crossing S.S. relay is many times less than needed. (((73))) Phil, K5PC
|