Don't know about these days, but used to use TV high-voltage lead ...
available in bulk at TV/electronic wholesale parts stores. Coax works
swell, too .. I used to use RG-8 with over 5500 volts (4-1000
amplifiers) --- never had a problem.
73, Mark AA6DX
----- Original Message -----
From: "Frank Goenninger" <frank_goenninger@t-online.de>
To: <amps@contesting.com>
Sent: Saturday, April 10, 2004 12:45 PM
Subject: [Amps] HV cable for abt 200 degrees celsius?
> Hi all:
>
> Yet another question for building this GU-84b based amp:
>
> What cables would you suggest (and where to get that in Europe) for the
> High Voltage (abt 4 kV) connections within the amp and between the amp
> and the PS?
>
> Which insulation to take? PE, VPE?
>
> Thx es 73 de Frank DG1SBG
>
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
>
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|