Amps
[Top] [All Lists]

Re: [Amps] HV cable for abt 200 degrees celsius?

To: <frank_goenninger@t-online.de>, <amps@contesting.com>
Subject: Re: [Amps] HV cable for abt 200 degrees celsius?
From: "AA6DX" <aa6dx@pacbell.net>
Reply-to: AA6DX <aa6dx@pacbell.net>
Date: Sat, 10 Apr 2004 20:56:51 -0700
List-post: <mailto:amps@contesting.com>
Don't know about these days, but used to use TV high-voltage lead ...
available in bulk at TV/electronic wholesale parts stores.  Coax works
swell, too .. I used to use RG-8 with over 5500 volts (4-1000
amplifiers) --- never had a problem.
73, Mark  AA6DX
----- Original Message ----- 
From: "Frank Goenninger" <frank_goenninger@t-online.de>
To: <amps@contesting.com>
Sent: Saturday, April 10, 2004 12:45 PM
Subject: [Amps] HV cable for abt 200 degrees celsius?


> Hi all:
>
> Yet another question for building this GU-84b based amp:
>
> What cables would you suggest (and where to get that in Europe) for the
> High Voltage (abt 4 kV) connections within the amp and between the amp
> and the PS?
>
> Which insulation to take? PE, VPE?
>
> Thx es 73 de Frank DG1SBG
>
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
>


_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

<Prev in Thread] Current Thread [Next in Thread>