>Thanks for the help.
>So Mr. Measures asked the following question as seen below. So I tune
>up to find the answers. Mind you I just installed a vhf parasitic kit
>today.
>I now get decent output with no extra heat or filament glow. Tubes are
>weak so take outputs with this in mind.
>Input Swr 1.0:1
** Is the SB-220's 20m tuned input modified? Normally, the 17m input
SWR is over 2 to 1 using the 20m switch position.
>Plate amp. 0.6
>Grid millamp 210
>output swr 1.4:1
>exciter watts 84
>output 775 watts
>
>Two conclusions. Its an intermitant problem or the parasitic kit
>altered something.
>
>Maybe human error but I doubt it. I tried tuning it up on two different
>days. With the same low power out on both days.
> Thanks
>Peter
>KC0NYG
>"R. Measures" <r@somis.org> wrote:
>
>>
>>
>>>I recently aquired a sb-220. When I try to tune up the amp on 17 meters
>>>using the 15 meter band switch I get only 300 watts out and both tubes
>>>really are working hard.
>>
>>** What is the plate/anode current reading with key-down/AØ emission on
>>the CW tap? What is the input SWR? Tnx
>>
>>>I get 1kw out on 15 meters and 20 meters. Is
>>>my plate choke resonating about 18 mhz ? Any help would be appreciated.
>>>Peter
>>>KC0NYG
>>>
>>>
>>>
>>>_______________________________________________
>>>Amps mailing list
>>>Amps@contesting.com
>>>http://lists.contesting.com/mailman/listinfo/amps
>>>
>>
>
>__________________________________________________________________
>New! Unlimited Netscape Internet Service.
>Only $9.95 a month -- Sign up today at http://isp.netscape.com/register
>Act now to get a personalized email address!
>
>Netscape. Just the Net You Need.
>
>
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|