To: | aa6eg@hotmail.com, K1LE@ARRL.NET, amps@contesting.com |
---|---|
Subject: | Re: [Amps] L-7 Failure, HV fuses |
From: | peter.chadwick@Zarlink.Com |
Date: | Mon, 17 Nov 2003 08:54:34 +0000 |
List-post: | <mailto:amps@contesting.com> |
Pat said; >I have seen in the literature descriptions of a HV fuse made by inserting >into the B+ line, a 30 guage Cu wire approx 2" long. suspended between >two ceramic standoffs in the amp. 30 gauge might be a bit on the thick side. I successfully use 40 SWG. 73 Peter G3RZP _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [Amps] More Eimac Info + some web data wanted., Mike Hyder --N4NT-- |
---|---|
Next by Date: | RE: [Amps] Benefits of 3-phase power?, peter . chadwick |
Previous by Thread: | Re: [Amps] L-7 Failure, HV fuses, Jeffrey Madore |
Next by Thread: | [Amps] Bleeder Resistor Qusetion, Steve |