>True, but in my opinion the bouncing doesn't stop as 
>fast as people are reporting here.

**  I measured the time for complete closure with a Hewlett Packard 1706 
o'scope.

> I consider the 
>4mS value more realistic based on my actual 
>measured examples. 
>-
>skipp
>-
>--------- Forwarded message ----------
>From: 2 <2@dock.net>
>**  all contacts - except mercury-wetted contacts - bounce.
>
>
>>--------- Forwarded message ----------
>>From: 2 <2@vc.net>
>>**  Using 120VDC, and a series-R to limit I to 80mA, a 26v HC-1 or RJ1A 
>>will make and stop bouncing its NO contacts in 1.8mS.  Using a 26v PS, 
>>the measured speeds were 6 - 7 mS.  
>
>
>________________________________________________________________
>The best thing to hit the internet in years - Juno SpeedBand!
>Surf the web up to FIVE TIMES FASTER!
>Only $14.95/ month - visit www.juno.com to sign up today!
>_______________________________________________
>Amps mailing list
>Amps@contesting.com
>http://lists.contesting.com/mailman/listinfo/amps
>


Rich, AG6K, 805-386-3734, www.vcnet.com/measures