>True, but in my opinion the bouncing doesn't stop as
>fast as people are reporting here.
** I measured the time for complete closure with a Hewlett Packard 1706
o'scope.
> I consider the
>4mS value more realistic based on my actual
>measured examples.
>-
>skipp
>-
>--------- Forwarded message ----------
>From: 2 <2@dock.net>
>** all contacts - except mercury-wetted contacts - bounce.
>
>
>>--------- Forwarded message ----------
>>From: 2 <2@vc.net>
>>** Using 120VDC, and a series-R to limit I to 80mA, a 26v HC-1 or RJ1A
>>will make and stop bouncing its NO contacts in 1.8mS. Using a 26v PS,
>>the measured speeds were 6 - 7 mS.
>
>
>________________________________________________________________
>The best thing to hit the internet in years - Juno SpeedBand!
>Surf the web up to FIVE TIMES FASTER!
>Only $14.95/ month - visit www.juno.com to sign up today!
>_______________________________________________
>Amps mailing list
>Amps@contesting.com
>http://lists.contesting.com/mailman/listinfo/amps
>
Rich, AG6K, 805-386-3734, www.vcnet.com/measures
|