To: | <amps@contesting.com> |
---|---|
Subject: | [Amps] 4-250B or QB3.5/750 in GG operation |
From: | DF3KV at aol.com (DF3KV@aol.com) |
Date: | Sun May 11 09:14:03 2003 |
In einer eMail vom 10.05.03 19:45:18 (MEZ) - Mitteleurop. Sommerzeit schreibt pe2six@xs4all.nl: > One other question on the 4-250B or qb3.5/750 in GG configuration. > When using aprox. 2.7 Kv I'm building an amp with two of those tubes > parallel. Now i'm looking for the value of the bias zener to get them to > run in class AB. > Hi Erwin, With 2,7KV there will be no need for Zeners in high? configuration, idling current will be quite low (class B). If used as tetrodes you are better off with adjustable grid -voltages 73 Peter |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | [Amps] Protecting the control grid of a tetrode, Phil Clements |
---|---|
Next by Date: | [Amps] chain/sprocket, PAUL HEWITT |
Previous by Thread: | [Amps] 4-250B or QB3.5/750 in GG operation, 2 |
Next by Thread: | [Amps] Protecting the control grid of a tetrode, Bill Coleman N2BC |
Indexes: | [Date] [Thread] [Top] [All Lists] |