Date: Tue, 6 Nov 2001 20:00:14 -0800
>
>Many thanks for the relays to my first post. A couple of points I left out.
>The t'bolt is tuned qrid input with one exception. It has a RES input 
>position which is used for any exciter that will load into a 350 ohm load. 
>RES means resistor. The is a 350 ohm resistor that terminates the exciter 
>in this position. It is used in the am and ssb modes. Since modern 
>equipment will not load into this I was hoping to change this resistor to 
>50 ohm. 

//   Good idea.  

>This RES position disconnects the tuned input and places this above 
>mentioned swamping resistor across the  grid ckt of the 4-400's. For some 
>reason this position is NOT used for cw operation. The amp runs class C for 
>cw and runs class AB2 for am and ssb.

//   Class AB2 is not linear with a grid driven 4-400.  Class AB1 is 
linear.
 
>The HV power supply uses the following: 4800 VCT at 500 mills HV 
>transformer. Choke input filter with a swinging choke. 25 hy at 80 mills to 
>5 hy at 500 mills. Filter cap is 8 MFD oil at 2000VDC although the hv is 
>2200 volts! It has a bunch of 0C3's in a separate screen supply for 
>regulation (4). Ill give more info on the grid supply later (after I figure 
>it out!)
>I would like to either improve the HV supply and increase the plate voltage   
>if u folks think it would be a good idea or leave  the HV as is and maybe 
>increase or improve the HV filtering. I know if I increase the HV, ill have 
>to change the screen and bias voltages to maintain the tubes at proper 
>class of operation. 

To run optimally in Class AB1, it takes c. 800v on the screen and much 
more anode potential than 2kV.   

> A few months ago I emailed Mr. Measures about this amp 
>and he said I should change the HV filter to a resonant choke filter for SSB
>operation. 

//   A swinging choke can not be resonated, so running C-input filtering 
might be best.  This would require nore C at more V, so electrolytic caps 
would be a good solution.  V-out on SSB should be c. 3k. 

>One more thing........the tubes are at grounded cathode but the 
>rig does NOT use center tapped filament transformers. It uses 1 transformer 
>with 2 separate secondary windings, 1 for each tube. At the tube , one side 
>of the filament is tied to ground and there are 2 .005 caps tied across the 
>filament terminals of each tube. I always thought this was a  bad idea 
>because this only one side of the filament is at DC ground, not both sides 
>as it would be with the center tap of the filament transformer tied to 
>ground. I hope u all got that!!!!

//   Henry and Kenwood do essentially the same thing.  If it works, why 
fix it?

cheers, Bill

-  R. L. Measures, 805.386.3734,AG6K, www.vcnet.com/measures.  