Amps
[Top] [All Lists]

[AMPS] More t'bolt questions

To: <amps@contesting.com>
Subject: [AMPS] More t'bolt questions
From: willy@global2000.net (Bill Russell)
Date: Tue, 06 Nov 2001 20:39:16 -0500
Many thanks for the relays to my first post. A couple of points I left out.
The t'bolt is tuned qrid input with one exception. It has a RES input 
position which is used for any exciter that will load into a 350 ohm load. 
RES means resistor. The is a 350 ohm resistor that terminates the exciter 
in this position. It is used in the am and ssb modes. Since modern 
equipment will not load into this I was hoping to change this resistor to 
50 ohm. This RES position disconnects the tuned input and places this above 
mentioned swamping resistor across the  grid ckt of the 4-400's. For some 
reason this position is NOT used for cw operation. The amp runs class C for 
cw and runs class AB2 for am and ssb.
The HV power supply uses the following: 4800 VCT at 500 mills HV 
transformer. Choke input filter with a swinging choke. 25 hy at 80 mills to 
5 hy at 500 mills. Filter cap is 8 MFD oil at 2000VDC although the hv is 
2200 volts! It has a bunch of 0C3's in a separate screen supply for 
regulation (4). Ill give more info on the grid supply later (after I figure 
it out!)
I would like to either improve the HV supply and increase the plate voltage 
if u folks think it would be a good idea or leave  the HV as is and maybe 
increase or improve the HV filtering. I know if I increase the HV, ill have 
to change the screen and bias voltages to maintain the tubes at proper 
class of operation. A few months ago I emailed Mr. Measures about this amp 
and he said I should change the HV filter to a resonant choke filter for SSB
operation. One more thing........the tubes are at grounded cathode but the 
rig does NOT use center tapped filament transformers. It uses 1 transformer 
with 2 separate secondary windings, 1 for each tube. At the tube , one side 
of the filament is tied to ground and there are 2 .005 caps tied across the 
filament terminals of each tube. I always thought this was a  bad idea 
because this only one side of the filament is at DC ground, not both sides 
as it would be with the center tap of the filament transformer tied to 
ground. I hope u all got that!!!!
Again folks, thanks in advance...........more to come!!!

One off topic question.................when ppl post anything to this 
group, I get the posts twice.......hmmmm.

Bill Russell
KC2IFR


--
FAQ on WWW:               http://www.contesting.com/FAQ/amps