>> >so the maximum anode to grid potential is 5750v during the cutoff-half of
>> >each
>> cycle
>> 
>> Is it not the case that this is only true when the loading is correct?
>> 
>> 73
>> 
>> Peter G3RZP
>
>That's right Peter. That is ONLY true when loading is correct for the 
>amount of drive. You can easily have several times that voltage in 
>an amplifier that isn't class A.
>
/\   Always blame the customer.  
> ...
cheers

-  R. L. Measures, 805.386.3734,AG6K, www.vcnet.com/measures.  