Amps
[Top] [All Lists]

[AMPS] SB-220: Operate/Standby Switch

To: <amps@contesting.com>
Subject: [AMPS] SB-220: Operate/Standby Switch
From: i4jmy@iol.it (i4jmy@iol.it)
Date: Fri, 2 Feb 2001 11:11:59 +0100
> >If you can adjust driving power to obtain the desired out, the CW 
> >position becomes basically meaningless, expecially if considering 
that 
> >tubes work better at 3Kv plate voltage.
> 
> CW has c. 2x the duty-cycle of SSB.  The SB-220's HV transformer is 
too 
> light for CW on the SSB tap.  The same thing is true for the TL-922.  
> 
> ciao, Mauri.
> 
> -  Rich..., 805.386.3734, www.vcnet.com/measures.  
> end


Reducing the drive power and consequently the output power, the RMS 
developed for a stated duty cycle is accordingly reduced.

Ciao, Rich

73,
Mauri



--
FAQ on WWW:               http://www.contesting.com/FAQ/amps
Submissions:              amps@contesting.com
Administrative requests:  amps-REQUEST@contesting.com
Problems:                 owner-amps@contesting.com


<Prev in Thread] Current Thread [Next in Thread>