To: | <amps@contesting.com> |
---|---|
Subject: | [AMPS] SWR Protection |
From: | W8JI@contesting.com (Tom Rauch) |
Date: | Sun, 3 Dec 2000 20:55:14 -0500 |
> >These voltages are summed at radio frequencies and the sum fed > >to a voltmeter system. > ______________________________________________________ > > This is why I suggested the gentleman use a fault detector which > monitors both RF voltage and current separately and trips when either one > exceeds a limit. Summing them together and monitoring only the sum may > not cause a trip under certain fault conditions. What fault condition can do that Bill? I certainly can't think of one! On the other hand I can think of conditions where SWR is very high and voltage and current look perfectly OK when taken as scalar values. I guess I don't follow your point. 73, Tom W8JI w8ji@contesting.com -- FAQ on WWW: http://www.contesting.com/FAQ/amps Submissions: amps@contesting.com Administrative requests: amps-REQUEST@contesting.com Problems: owner-amps@contesting.com |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | [AMPS] SWR Protection, Tom Rauch |
---|---|
Next by Date: | [AMPS] SWR Protection, Steve |
Previous by Thread: | [AMPS] SWR Protection, Bill Turner |
Next by Thread: | [AMPS] SWR Protection, Bill Turner |
Indexes: | [Date] [Thread] [Top] [All Lists] |