| To: | <amps@contesting.com> |
|---|---|
| Subject: | [AMPS] SWR Protection |
| From: | w7ti@jps.net (Bill Turner) |
| Date: | Sun, 03 Dec 2000 16:26:36 -0800 |
On Sun, 3 Dec 2000 20:34:07 -0500, Tom Rauch wrote: >The current is read via transformer coupling to the line which >converts line current to voltage. Voltage is read by a voltage divider >either with capacitors or a transformer. > >These voltages are summed at radio frequencies and the sum fed >to a voltmeter system. ______________________________________________________ This is why I suggested the gentleman use a fault detector which monitors both RF voltage and current separately and trips when either one exceeds a limit. Summing them together and monitoring only the sum may not cause a trip under certain fault conditions. 73, Bill W7TI -- FAQ on WWW: http://www.contesting.com/FAQ/amps Submissions: amps@contesting.com Administrative requests: amps-REQUEST@contesting.com Problems: owner-amps@contesting.com |