> >>>lots of parasitics.  But never once did I see a parasitic cause damage.
> 
> 
> Boy now thats a parasitic I wouldnt mind having,  all the 
> parasitics that I have seen , most of them around the 
> 4-1000 amplifiers, cause damage to say the least.  When 
> the amp takes off uncontrollably and meters bend around 
> the pegs, resistors blow, safety trips explode, that what 
> I call damage.  

Sounds like you have confused outgassing or gas ingress, a fairly 
common occurrence, with a parasitic.

High vacuum arcs are  common in tubes, especially old used glass 
tubes.

I guess if we don't know what a problem is, it's easy to call it a 
"parasitic".




73, Tom W8JI