Amps
[Top] [All Lists]

[AMPS] One more failure mode

To: <amps@contesting.com>
Subject: [AMPS] One more failure mode
From: measures@vc.net (Rich Measures)
Date: Tue, 13 Apr 1999 10:24:43 -0700


>
>>Another question. What is the RF current derating by frequency when a
>>switch is factory specified at 115VAC 60Hz ?
>
?  Depends on the frequency.  At 28MHz, 20A-@60Hz contacts might be good 
for 5A continuous.  

>>And still another question:
>
>What is the rating of that switch in an environment of elevated 
>temperature?  Keep in mind that inside an amplifier cabinet, you won't 
>have 25 C temperatures.  Plus the switch itself will get hot or warm due 
>to the RF current flowing through it.  All these serve to derate the 
>device.
>
?  Good points.  This is probably why Heath used two, paralleled sets of 
output bandswitch contacts as well as bandswitch forced air cooling in 
the SB-220.  .  
>
-  later, Jon


Rich...

R. L. Measures, 805-386-3734, AG6K, www.vcnet.com/measures  


--
FAQ on WWW:               http://www.contesting.com/ampfaq.html
Submissions:              amps@contesting.com
Administrative requests:  amps-REQUEST@contesting.com
Problems:                 owner-amps@contesting.com
Search:                   http://www.contesting.com/km9p/search.htm


<Prev in Thread] Current Thread [Next in Thread>