Amps
[Top] [All Lists]

Re: [Amps] Simpson 260 question

To: "Val Erwin" <valerwin@att.net>, <amps@contesting.com>, <K1SG@aol.com>
Subject: Re: [Amps] Simpson 260 question
From: Karl-Arne Markström <sm0aom@telia.com>
Date: Mon, 3 Aug 2009 21:46:08 +0200
List-post: <amps@contesting.com">mailto:amps@contesting.com>
I would strongly advise against measuring non-current limited amplifier 
plate voltages in the kV region with the standard Simpson 260.

The internal and external flash-over distances are not sufficiently long for 
any safety margins, and hairline cracks, dust and dirt may create stray 
current leakage paths.

In the 60's, there was a fatal accident at my 'Alma Mater' ,Chalmers Univ. 
of Tech., when a research engineer tried to monitor the cavity voltage of a 
large Klystron using a Simpson multimeter, which flashed over to his body 
through the phenolic case.

When measuring plate voltages, a properly insulated voltage divider made of 
many series connected high-voltage resistor is the recommended method.

73/

Karl-Arne
SM0AOM




----- Original Message ----- 
From: "Val Erwin" <valerwin@att.net>
To: <amps@contesting.com>; <K1SG@aol.com>
Sent: Monday, August 03, 2009 9:29 PM
Subject: Re: [Amps] Simpson 260 question


Howdy Steve........

This should give you all the info you need:

http://www.simpson260.com/260-5/simpson_260-5.htm


Best regards,

Val Erwin, W5PUT

--- On Mon, 8/3/09, K1SG@aol.com <K1SG@aol.com> wrote:


From: K1SG@aol.com <K1SG@aol.com>
Subject: [Amps] Simpson 260 question
To: amps@contesting.com
Date: Monday, August 3, 2009, 7:16 PM


I have a Simpson 260, Series 5. What I don't have is the manual for it.
What I'd most like to know is what accuracy it's rated for on the 5000 volt
scales, both AC and DC. I believe the meter is rated for 2% of full scale
accuracy up to 1000 volts DC and 3% on AC, but I haven't been able to track
down a number for the HV scales.

Your help, as always, is appreciated!
Steve

Steve Gilbert
K1SG
K1SG@AOL.com
508-435-9133
FN42fe
**************A Good Credit Score is 700 or Above. See yours in just 2 easy
steps!
(http://pr.atwola.com/promoclk/100126575x1222846709x1201493018/aol?redir=http://www.freecreditreport.com/pm/default.aspx?sc=668072&hmpgID=115&bcd
=JulystepsfooterNO115)
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps


--------------------------------------------------------------------------------



No virus found in this incoming message.
Checked by AVG - www.avg.com
Version: 8.5.392 / Virus Database: 270.13.42/2279 - Release Date: 08/03/09 
05:57:00

_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

<Prev in Thread] Current Thread [Next in Thread>