To: | "'AMPS'" <amps@contesting.com> |
---|---|
Subject: | Re: [Amps] Step start |
From: | "Peter Voelpel" <df3kv@t-online.de> |
Date: | Sun, 3 Feb 2008 16:36:34 +0100 |
List-post: | <mailto:amps@contesting.com> |
That is one of the reasons that standard solid state relays will not soft start transformers as they won´t switch on the peak of the sine wave but at zero volts 73 Peter -----Original Message----- From: amps-bounces@contesting.com [mailto:amps-bounces@contesting.com] On Behalf Of David Cutter I have a 240V 15A variac which would consistently blow a 13A plug fuse at switch on, unloaded. The spec for these plug fuses states they must blow in 30s with 2.1 x nominal current applied, ie >27A: these always blew instantly. Slow blow fuses did not work either. The variac looks like a short across the mains until the magnetising current is established. _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [Amps] Step start, David Cutter |
---|---|
Next by Date: | [Amps] QRO-parts - sound kinda fishy now, steve d |
Previous by Thread: | Re: [Amps] Step start, David Cutter |
Next by Thread: | Re: [Amps] Step start, Gary Schafer |