- 1. [TowerTalk] HDX-555 relay settings (score: 1)
- Author: "Ed Magnuson" <w1mag@bellatlantic.net>
- Date: Mon, 30 Aug 2010 14:39:02 -0400
- I am new to this group and hope this is an appropriate question. I acquired an HDX-555 from a ham's widow and have had a problem with the time delay relays that control the motor drive. I wish to rep
- /archives//html/Towertalk/2010-08/msg00639.html (7,012 bytes)
- 2. Re: [TowerTalk] HDX-555 relay settings (score: 1)
- Author: "Ed Magnuson" <w1mag@bellatlantic.net>
- Date: Mon, 30 Aug 2010 16:15:09 -0400
- Thanks, Doug. I will set them both the same and for about 2 seconds and see if that works. My tower is at our country place, which we visit on week-ends so will check it out then. This problem follow
- /archives//html/Towertalk/2010-08/msg00643.html (8,057 bytes)
- 3. Re: [TowerTalk] HDX-555 relay settings (score: 1)
- Author: "Ed Magnuson" <w1mag@bellatlantic.net>
- Date: Mon, 30 Aug 2010 19:53:40 -0400
- I'm patting myself on the back now for finding TowerTalk and getting so many quick replies and good answers to my question. I thank you all. I must apologize to U.S. Towers. After posting my query an
- /archives//html/Towertalk/2010-08/msg00655.html (8,521 bytes)
- 4. Re: [TowerTalk] Retracting crankup tower in horizontal position (score: 1)
- Author: "Ed Magnuson" <w1mag@bellatlantic.net>
- Date: Fri, 08 Oct 2010 13:45:40 -0400
- ?I have an HDX-555 crank-up with tiltover. When the tower was installed by XXTowers, they used the motor to extend it while horizontal to install the Tailtwister. They had no trouble retracting the t
- /archives//html/Towertalk/2010-10/msg00069.html (8,180 bytes)
- 5. [TowerTalk] MCL-100 limit switches (score: 1)
- Author: "Ed Magnuson" <w1mag@bellatlantic.net>
- Date: Fri, 07 Jan 2011 12:08:00 -0500
- Since US Tower rarely divulges such information, can anyone who has the MCL-100 control box and limiting switches tell me who manufactures the switches and their part numbers? I seem to have a faulty
- /archives//html/Towertalk/2011-01/msg00145.html (7,930 bytes)
- 6. Re: [TowerTalk] MCL-100 limit switches (score: 1)
- Author: "Ed Magnuson" <w1mag@bellatlantic.net>
- Date: Fri, 07 Jan 2011 14:25:18 -0500
- Thanks for the great tips, Dan, Mike and Jim. I'm sure I can run one of those switches down now with this info. May start with Grainger. Will check out Allen-Bradley switches, too. And Dan, if you ha
- /archives//html/Towertalk/2011-01/msg00152.html (8,659 bytes)
- 7. Re: [TowerTalk] TowerTalk Digest, Vol 97, Issue 43 (score: 1)
- Author: "Ed Magnuson" <w1mag@bellatlantic.net>
- Date: Mon, 17 Jan 2011 15:21:17 -0500
- I have had the relay problem with my HDX-555 and plugging in a good spare fixed it, as suggested here. I have also had the lower limit switch trigger rod get out of line and used a pliers to fix it.
- /archives//html/Towertalk/2011-01/msg00274.html (30,502 bytes)