Certainly relays can be a failure point. Sealed relays in modern rigs
may still arc or oxidize at the contacts, and I have even seen relays
that were not seated to the solder pads fully, before the board was
soldered. That was in a Kenwood, but could happen to any relay equipped
device.
I also suggested the power buses as a point to check for solder problem joints, and electrolytics that maybe only have a 20 year lifetime. Stuart Rohre K5KVH _______________________________________________ TenTec mailing list TenTec@contesting.com http://lists.contesting.com/mailman/listinfo/tentec |