| List-post: | <mailto:tentec@contesting.com> |
Bob and the gang When the new parts come in I plan on changing out the reset cap since the pcb will be pulled. I mean why not? Mike wb8vge Sent from my iPhone On Aug 22, 2013, at 5:37 PM, "Bob McGraw - K4TAX" <RMcGraw@Blomand.net> wrote: > As a general rule, electrolytic caps decrease in value as they age. That > being the case here, the value could now be 1/4 of its original value and > which makes the simple RC timing just too fast for the system to load and > boot. A new cap or one that's 50% larger might just solve the problem. > > 73 > Bob, K4TAX > > > > > ----- > |