Hi Wade,
Just looked at my manual, and your memory serves you well.
Looks like a likely cause of the problem.
73
Tim
gm4lmh
--------------------------------------------------
From: "wade staggs" <tvman1954@gmail.com>
Sent: Saturday, July 14, 2012 2:33 PM
To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
Subject: Re: [TenTec] Paragon Problem
*Ben,*
* Don't lose hope yet. I have a copy of the schematic. I do however
remember the two electrolytic caps on the input ( red wire ) giving
trouble. one is a 33uf @16 volts and the other 10uf @16volts. My memory is
going but, believe that one or the other have shorted in the past causing
the same problem that you now have. They are C25 and C24 ( If the board is
labeled ) If needed, I will drag out my old flat bed scanner and do my
best
to get you a copy of the PA section. While you are in there, replace the 2
caps anyway. Temp rating 105c and higher voltage. *
* 73 de
Wade/KJ4WS*