TenTec
[Top] [All Lists]

[TenTec] Testing Argosy final amp current

To: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Subject: [TenTec] Testing Argosy final amp current
From: John <jh.graves@verizon.net>
Reply-to: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Sun, 26 Feb 2012 00:02:52 -0500
List-post: <mailto:tentec@contesting.com>
After considering several different approaches, I concluded that cutting the red lead at about the center of the run was both the easiest to access and easiest to repair. The deed is done.

With a dummy load on the Argosy ( nothing said to put a load on the output but it seemed logical at the time) I measured the current with the output set to high and drive set to 1. At 1 and below, the current is about 60-80 ma. The manual says the quiescent current should be 125 ma with the gain set all the way clockwise. I see 150 ma with the gain set about at 2. With the gain at about 8 the current rose to close to 800 ma. The measurement is taken after putting the mode control at LOCK. Am I doing something incorrectly? Does anybody have any thoughts or corrections to my measurement process?. Given the difficult replacement of the finals, I am reluctant to just play.

John / WA1JG

--
John / WA1JG