TenTec
[Top] [All Lists]

Re: [TenTec] OII SWR Indication Off on 10 m

To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
Subject: Re: [TenTec] OII SWR Indication Off on 10 m
From: GARY HUBER <glhuber@msn.com>
Reply-to: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Mon, 6 Feb 2012 11:52:48 -0600
List-post: <mailto:tentec@contesting.com>
Probably the actual VSWR AT the interal sensor. Add an electrical 10 M 1/4 wave jumper in current dummy load circuit to determine if it is due to current line length and impedance.


73 ES DX,
Gary -- AB9M

-----Original Message----- From: Kim Elmore
Sent: Monday, February 06, 2012 11:38 AM
To: Discussion of Ten-Tec Equipment
Subject: Re: [TenTec] OII SWR Indication Off on 10 m

While I suppose that's a possibility, it makes no sense that this
appears only on 10 m and not 12 m. Of course, the tuner can be
bypassed -- doing so makes no difference. I bypassed the internal
tuner and used my external tuner to get a 1.0:1 match. The display
shows me 1.6:1, which is exactly what it shows me when the internal
tuner believes it has found a match.

I'm stumped...

Kim N5OP

At 07:42 AM 2/6/2012, you wrote:
Ah, you're using the internal tuner.  I don't have one.  Maybe it's a tuner
issue?

73 Ray W2RS
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec

_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec