That's interesting to hear because I don't get such fast QSK with my
O II. For CW I have it set as 0% delay, internal keyer off (I use an
external unit just because) and CW rise/fall at 3 mS (as fast as it
can be set) and SSB: CW Jack PTT on. Will any of these result in
slowing down the QSK capability?
Kim N5OP
At 04:09 AM 11/17/2011, you wrote:
On Thu, Nov 17, 2011 at 2:21 AM, Robert Carroll <w2wg@comcast.net> wrote:
> When you call Paul, also ask the following questions:
>
> 1) What is the maximum speed at which the Orion provides intersymbol QSK
> using the internal keyer
> 2) What is the maximum speed at which the Orion provides intersymbol QSK
> using an external keyer.
>
FWIW, I get about 60wpm on my Orion and still enough unmuting between
characters to just tell that someone is on frequency. That's external
keyer, pc generated. I can't key fast enough to measure with internal
keyer.
The answer also depends on cw rise/fall setting. It will be a few wpm
faster with the lowest rise/fall setting and a few wpm slower with the
highest rise/fall settings.
Barry N1EU
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
|