TenTec
[Top] [All Lists]

Re: [TenTec] Orion's break in

To: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Subject: Re: [TenTec] Orion's break in
From: Floyd Sense <floyd@k8ac.net>
Reply-to: floyd@k8ac.net, Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Sun, 13 Nov 2011 19:11:45 -0500
List-post: <mailto:tentec@contesting.com>
An interesting question. I wonder if the Orion and Orion 2 differ in this respect. On my Orion 2, I can use the CW delay to achieve semi-break-in, but I still hear the same relay clacking away. I expected to hear the relay only at the beginning and end of a transmission, but that's not the case - it still follows the keying, although the receiver is properly muted for the delay set with the CW delay function. So, maybe Toshimi's desire to eliminate the relay noise is not satisfied this way.

73, Floyd - K8AC


On 11/13/2011 5:56 PM, Barry N1EU wrote:
Menus - CW - CW QSK Delay

start with 25% and increase/decrease as necessary

73,
Barry N1EU

On Sun, Nov 13, 2011 at 10:39 PM, Rick - DJ0IP / NJ0IP<Rick@dj0ip.de>  wrote:
Hi Toshimi,

You can adjust the delay of the TR relay.
If you select a delay, then it is effectively semi BK and no longer QSK.
This was added to the rig after the initial release so it probably was not
in the manual.
Maybe someone who owns an Orion can jump in and tell you exactly how to
adjust it.  I have forgotten.

73
Rick, DJ0IP

-----Original Message-----
From: tentec-bounces@contesting.com [mailto:tentec-bounces@contesting.com]
On Behalf Of Toshimi Horie
Sent: Sunday, November 13, 2011 11:32 PM
To: tentec@contesting.com
Subject: [TenTec] Orion's break in

Hi all. I am JE2UFF.

This month, I got the Orion of used one from US.

I just start operation with it. I can checked user manual, but not found.

So please tell me for everyone.
The Orion has semi break in mode? I have other rig. That's japanese one.
Normaly, japanese transceiver has two kind of break in operation mode. It's
semi and full break in.

The Orion do the CW mode, each mores code can switch the relay. It is very
noisy. Is this normal specs?

If it has semi break in mode then the relay can switch for start and finish
of two times. Very quaiet.

Thanks all
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec

_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec

_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec


<Prev in Thread] Current Thread [Next in Thread>