TenTec
[Top] [All Lists]

Re: [TenTec] 425 Failure

Subject: Re: [TenTec] 425 Failure
From: Jim Brown <k9yc@audiosystemsgroup.com>
Reply-to: k9yc@arrl.net, Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Tue, 16 Aug 2011 09:43:13 -0700
List-post: <mailto:tentec@contesting.com>
On 8/16/2011 9:00 AM, Art Trampler wrote:
The "only" arc that occurred was within the (teflon) insulated HV line feeding the plate caps from the RF choke. It appears that the wire inside broke...maybe it was already compromised...under the high current drain.

That's the arc I'm talking about -- may have been within the tubes, or very high voltage generated by the overdrive condition. Some sort of arc fried that wiring and the choke.

Another point. On at least one of my amps, the HV choke looks like it's been warm, with a few turns of the wire a bit loose at the top. That amp works just fine.

73, Jim K9YC

<Prev in Thread] Current Thread [Next in Thread>