TenTec
[Top] [All Lists]

Re: [TenTec] Gauge of wire from power supply question?

To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
Subject: Re: [TenTec] Gauge of wire from power supply question?
From: "Eugene Klingler" <n8zx@hughes.net>
Reply-to: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Wed, 6 Jun 2007 16:37:03 -0400
List-post: <mailto:tentec@contesting.com>
mynew o2 came with a factory tentec #14 supply cablel. because of another issue, paul clinton sent me a #12 cable.....now i find that either one works fine. i dont know what cable is being shipped with th current new o2's. gene klingler n8zx n8zx@hughes.net ----- Original Message ----- From: "Stuart Rohre" <rohre@arlut.utexas.edu>
To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
Sent: Wednesday, June 06, 2007 2:36 PM
Subject: Re: [TenTec] Gauge of wire from power supply question?


The MINIMUM power supply wire gauge for any 100 watt radio would be no. 12, as it is rated at the 20 amps your 100 watt radio likely pulls. Some of the latest radios pull 25 amps, and you would need no. 10 to be safe with them. You likely are seeing voltage sag regulation issues with the high IR drop of
14 ga. on power peaks.

-Stuart
K5KVH


_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec