I notice the same on this end....Paragon II, 238B atu and MFJ-259B
analyzer.
Also, my Mirage MP-2 wattmeters indicate a different power output reading
from the rig and atu if other than full power output from the Paragon II.
----- Original Message -----
From: <ARDUJENSKI@aol.com>
To: <tentec@contesting.com>
Sent: Wednesday, August 09, 2006 7:45 AM
Subject: [TenTec] Paragon II and SWR meter reading
I noticed that not in all cases will the meter (set to SWR) in the Paragon
II read exactly the same as that is the 238 ATU. By the way the 238 and
the
Paragon are connected by an 18 inch quality jumper (Belden 8214).
I found a discussion on the topic in the ARCHIVES at
_http://lists.contesting.com/archives//html/TenTec/2003-01/msg00663.html_
(http://lists.contesting.com/archives//html/TenTec/2003-01/msg00663.html)
Basically this section in short says to believe the meter in the rig.
SITUATION: I did notice that if I turn the AGC button to OFF the meter
will
match the ATU meter. (By the way I use a MFJ 249 Analyzer to find the
settings for the ATU but find in some cases it still needs to be tweeked
when I
push TUNE.) Is this normal? I could not find anything in the manual that
even
mentions the AGC in conjunction with operation of the SWR/TUNE set up.
Is this normal or do I have a problem I need to look into?
Thank you
Alan KB7MBI
Woodinville, WA