Hi Glenn,
   The 20A fast trip works fine and is what I use with mine. The
instant will give a little more protection but they are very hard
to get as POCO Sales does not stock them and wants an order of 50
I think before they will have airpax make them. I have an 18A
instant that I used on my Corsair II but the Jupiter pulls a
little more current and the 18A will trip frequently. I therefore
went with the 20A instant. Don't use a 22A or it may never trip.
I tried one and several times saw 27A and no trip since the trip
point if 135% or the rating. 
73 Jim K4CGY

--- Glenn Hess <glennhess@earthlink.net> wrote:

> I have seen numerous posts on the list here recommending AirPax
> breakers for Ten Tec transceivers using non-Ten Tec power
> supplies. Could someone tell me what model # I should use for a
> Jupiter?
> 
> 73, Glenn
> _______________________________________________
> TenTec mailing list
> TenTec@contesting.com
> http://lists.contesting.com/mailman/listinfo/tentec
> 


__________________________________________________
Do You Yahoo!?
Tired of spam?  Yahoo! Mail has the best spam protection around 
http://mail.yahoo.com 
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec

<Prev in Thread] Current Thread [Next in Thread>