TenTec
[Top] [All Lists]

Re: [TenTec] OMNI-5 clicking

To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
Subject: Re: [TenTec] OMNI-5 clicking
From: "Steve Sloane" <ssloane1@rcn.com>
Reply-to: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Fri, 16 Dec 2005 23:21:28 -0500
List-post: <mailto:tentec@contesting.com>
I placed a small piece of paper between the relay contacts...just lifted off 
the case ...worked fine, Steve
----- Original Message ----- 
From: "John Holliman" <w5ot@aol.com>
To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
Sent: Friday, December 16, 2005 4:00 PM
Subject: Re: [TenTec] OMNI-5 clicking


>I did number 2 except I installed a micropswitch on the back panel so
> the relay could be enabled when needed.
>
> Roy Koeppe wrote on 12/15/2005, 11:22 PM:
>
> > Asked,
> >
> > "When I send CW, I hear a relay clicking.  I'm guessing it has something
> > to do with non-QSK switching for a linear (which I don't have).  Is it
> > something I can disable to quiet the rig?"
> >
> > - Keith -
> > _______________________________________________
> >
> > Keith,
> >
> > #1.  Drive a toothpick between the relay armature and its core.   --OR--
> >
> > #2. Lift one end of the relay-driver transistor's base connection. It
> > can be re-soldered if ever needed.
> >
> > 73,   Roy    K6XK       Iowa
> >
> > _______________________________________________
> > TenTec mailing list
> > TenTec@contesting.com
> > http://lists.contesting.com/mailman/listinfo/tentec
> >
>
>
> _______________________________________________
> TenTec mailing list
> TenTec@contesting.com
> http://lists.contesting.com/mailman/listinfo/tentec
> 
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec