Then I think you need to adjust the master oscillator which
is the 20MHz osc trimmer on the logic board. That seems
pretty far off for it but maybe. The band oscillators
wouldn't all be all off 2K and the bfo's either. I would get
a frequency counter on it first though...probably at the
10MHz divided down output, pin 1, U13. Carefully.
Chuck, KE9UW
---- Original message ----
>Date: Mon, 25 Apr 2005 13:11:46 -0700 (PDT)
>From: Jorge A Mejia <laussana@yahoo.com>
>Subject: Re: [TenTec] Omni VI Pls VFO Frequency
Calibration
>To: tentec@contesting.com
>
>
>Yes chuck it it the same on every band
>
>Thank you
>Jorge HK4CZE
>
>On every band?
>Chuck, KE9UW
>
>
>>During a recent trip to the states I sent my Omni VI
>>Pls to the factory for a general "alignment". Now
>back
>>home I realize the vfo is about two Khz away from the
>>actual frequency. I have been investigating the
>manual
>>in detail but there seems to be nothing regarding
>this
>>adjustment .
>>
>>I would very much appreciate any info.
>>
>>Jorge/HK4CZE
>>