NJ0IP wrote:
> 2. The ACOM uses more sophisticated fault monitoring, especially with this
> ACR FAULT that is currently pestering many OM. The ARC FAULT on the ACOM
> has nothing to do with tube flashovers, but rather flags a condition where
> RF is seen at its input when the relay is not settled in the TX position.
Ah.....that sounds remarkably like what Alpha would report as a "T/R Fault".
> GUYS, BELIEVE ME, the "right people" in the "right places" are working
very
> hard on this issue.
Thank goodness. I'll sleep easy tonight :-))
> In answer to the speculation about whether the problem occurs when keying
> with the loop or the single cable, the answer is "both and neither". We
> found that we could key the ACOM permanently (externally) without any T/R
> keying cable between the two boxes and then just apply RF from the Orion
and
> the problem still occurs.
Apparently not a T/R fault then, albeit reported as one.
The plot thickens.
Bob, 5B4AGN, P3F