TenTec
[Top] [All Lists]

RE: [TenTec] GFI Problems

To: "tentec@contesting.com" <tentec@contesting.com>
Subject: RE: [TenTec] GFI Problems
From: "Jim Brown" <jim@audiosystemsgroup.com>
Reply-to: Jim Brown <jim@audiosystemsgroup.com>,tentec@contesting.com
Date: Tue, 14 Dec 2004 16:27:12 -0600
List-post: <mailto:tentec@contesting.com>
On Tue, 14 Dec 2004 15:24:39 -0500, Chuck Secrest wrote:

>In the end the only way I found to solve the problem
>was to replace the GFI with a standard circuit. 

When I fired up my Titan, I had a problem with one GFI in my bathroom and 
another in the kitchen. The one in the bathroom actually failed, so I changed 
it out and now it's fine. The one in the kitchen was causing the clock in the 
microwave connected to it to reset. I fixed that one with a 0.01uF from line 
(hot) to the outlet safety ground (green wire).  

Both of these GFI's are within 25 ft of the 80/40 antenna, and the one in the 
bathroom is about 15 below the end of my 20/15/10 dipole, but the wiring to 
them is in grounded EMT conduit. 

Jim Brown K9YC