TenTec
[Top] [All Lists]

RE: [TenTec] Orion Freezing + Current Drain

To: <tentec@contesting.com>
Subject: RE: [TenTec] Orion Freezing + Current Drain
From: "Rick Westerman" <Rick@dj0ip.de>
Reply-to: Rick@dj0ip.de, tentec@contesting.com
Date: Wed, 17 Dec 2003 17:04:14 +0100
List-post: <mailto:tentec@contesting.com>
Update on measured current drain:

In the upcoming ORION test in Funkamateur magazine, the testers
found the current drain to be band-dependent.  They measured
between 18 and 23.8 amps (at 13.8v) for full power out.

73
Rick

-----Original Message-----
From: tentec-bounces@contesting.com
[mailto:tentec-bounces@contesting.com]On Behalf Of John Rippey
Sent: Wednesday, December 17, 2003 2:03 PM
To: tentec@contesting.com
Subject: [TenTec] Orion Freezing


>John,
>
>The 961 and 962 don't really handle enough current to run the
>ORION (to full power).
>You need 24A for an ORION and the two older units cut off at
20A.
>
>73
>Rick
Rick:

Thanks for the info. I was wondering about that after I sent in
the
comment. The ORION manual says without 25 A the transmitter may
put out
less than 100 watts. I guess that means an Astron linear :-)

Anyhow, I may be old fashioned, but I would be just a little more
comfortable using a linear with the Orion.

73,
John, W3ULS

_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec


_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec

<Prev in Thread] Current Thread [Next in Thread>