Hi Ed...thanks for the feedback. I see you mis-read Tim's email the same
as I did. Tim said he had NO voltage at connector 41 on the PBT board. I
missed that statement when I read his email. And even if one of his
PIN's were open, there is still a DC path to ground via R22.
See your from Marietta!! I'm retiring and moving to my home town of
Valdosta at the end of this month. Cant seem to find much HF activity in
that part of GA? (Yet!!)
Tom/W4BQF
calderman AT cox.net
-----Original Message-----
From: tentec-bounces@contesting.com
[mailto:tentec-bounces@contesting.com] On Behalf Of Ed Tanton
Sent: Saturday, March 01, 2003 7:11 PM
To: tentec@contesting.com
Subject: RE: [TenTec] no voltage to 1.8 filter?
>///snip
>then U22 is working correct and the
>problem has to be wiring.
>
> Tom/W4BQF
///snip
Not necessarily Tom... one or both of Tim's OMNI VI PIN diode(s)
associated with that filter could be bad, and it would still act as you
describe. If the levels associated with the other PIN diodes when
selected-and when NOT selected-are the same as those for the non-working
filters' PIN diodes, then the PIN diode(s) should be the cause-as an
OPEN.
73 Ed Tanton N4XY <n4xy@earthlink.net>
Ed Tanton N4XY
189 Pioneer Trail
Marietta, GA 30068-3466
website: http://www.n4xy.com
All emails <IN> & <OUT> checked by
Norton AntiVirus with AutoProtect
LM: ARRL QCWA AMSAT & INDEXA;
SEDXC NCDXA GACW QRP-ARCI
OK-QRP QRP-L #758 K2 (FT) #00057
--------------------------------------------------
"Suppose you were an idiot ...
And suppose you were a member of
Congress... but I repeat myself."
--Mark Twain
--------------------------------------------------
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
|