Howdy --
 
    I've had several occasions in the last several  months to fix an 
intermittent problem on Force 12 linear loaded antennas. It  turns out that all 
of 
them had rusted U-bolts that had deteriorated and caused  intermittent 
electrical 
contact. The U-bolts are the real little ones that  connect the linear loaded 
wires and the shorting wire. 
 
    You would be well advised to include checking them  during your annual 
inspection and probably replacing them. Ultimately they will  all fail. 
 
Cheers,
Steve     K7LXC
TOWER TECH -
Professional tower services for hams
 
PS - You are doing an annual inspection aren't  you?!?
**************New MapQuest Local shows what's happening at your destination.  
Dining, Movies, Events, News & more. Try it out!      
(http://local.mapquest.com/?ncid=emlcntnew00000001)
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com