Hi Helmut,
I worked with Chip at Yaesu when we were adding support for the 1000MP to Log
Windows. What is in the manual is the full reference. There is a doc error
though, on Opcode 5 (VFO A./B) the param must always be a '1' to toggle the
VFO from A to B. (You can't tell it which VFO to go to, just to toggle the
VFO). I told Chip about this, and he's updating it in the newer user manuals.
But what is in the 1000MP manual is ALL the CAT commands the 1000MP supports.
Many functions that the MP has are not supported in the CAT interface.
Rick - W4PC
http://www.logwindows.com
http://www.cssincorp.com
In a message dated 2/7/2001 14:52:14 PM Central Standard Time,
helmut@df7zs.de writes:
<< Hi There.
Where can I find a full reference of all commands
the FT-1000MP understands through his PC (CAT)
interface ?
There must be more stuff than you'll find in the manual.
Examples:
How to adjust output power via CAT ?
How to access the TUNE from FH-1 via CAT ?
Hackers guide needed.
73sss
Helmut
www.df7zs.de >>
--
FAQ on WWW: http://www.contesting.com/FAQ/yaesu
Submissions: yaesu@contesting.com
Administrative requests: yaesu-REQUEST@contesting.com
Problems: owner-yaesu@contesting.com
|