Jim,

I just checked my writelog.ini file and find the following lines in the [ENTRY] section:

LR=-1
RotatorPort=6
RotatorType=0

In looking at the Entry section in the Help manual it says "LR=1 -1 for neither, 1 means Right, 0 means Left" I have no idea what "LR" stands for and the manual doesn't specify it. Maybe you could play with this setting and see if it changes anything. My rotator com port is 6, it must be between 1 and 8, and my RotatorType=0. The manual says "RotatorType=1 DCU-1, Yaesu, etc.". My rotator is an old Create Design with a Green Heron controller box. It uses a USB connection and the DCU-1 protocol. I don't know why my ini file says RotatorType=0 and the manual says RotatorType=1. Again, you might try playing with this setting in the ini file to see if it makes a difference.

Do you happen to have another logger program that can control the rotator via a port command? In my case I use DXBase and can control my rotator from that software as well as WL. I think N1MM and others can do likewise. If so, try setting up the rotator interface in the other logger and see what happens there. If the problem repeats it probably isn't WL.

73,
Gary AL9A


----- Original Message ----- From: "JE Brown" <W4LC@fuse.net>
To: <writelog@contesting.com>
Cc: <CQ-contest@contesting.com>
Sent: March 17, 2013 5:51 AM
Subject: [WriteLog] Rotator Control Mystery


The DCU-2 control mystery continues. I have been trying to use my new Hy-Gain DCU-2 in the BARTG contest.

This has a built in chip, and only requires a USB cable to the PC. A virtual COM port was installed per the instructions and using the drivers called for. This port (COM8) shows in Device Mgr and reports to be working ok.

Writelog recognizes the port in "port setup", and the DCU-1 protocol is selected (same as DCU-2).

When a call or prefix is entered into the logging field, the bearing shows as it should in the Bearing box. Selecting RADIO>ANTENNA to XXX Azimuth from the top menu moves the rotator to the correct bearing as it should. But it will not do it again for any call or prefix. The correct bearing still shows in the RADIO>ANTENNA to XXX Azimuth for the next call or prefix, but the rotator does not get the command. Checking the Device Mgr, the COM8 still shows and reports to be working ok. The COM8 port and DCU-1 protocol still shows as being selected under "port setup".

Exiting Writelog, then restarting, Writelog remembers all settings, including COM8 and DCU-1 protocol. Again, the rotator will move to the correct bearing or prefix as entered in the logging box, but only once. Then not again.

I have reinstalled the drivers, but no luck.

The DCU-2 works just fine under manual control.

This must be something fairly simple, but I am out of ideas right now.

Any suggestions?

Jim   W4LC


_______________________________________________
WriteLog mailing list
WriteLog@contesting.com
http://lists.contesting.com/mailman/listinfo/writelog
WriteLog on the web:  http://www.writelog.com/


-----
No virus found in this message.
Checked by AVG - www.avg.com
Version: 2013.0.2904 / Virus Database: 2641/6178 - Release Date: 03/15/13


_______________________________________________
WriteLog mailing list
WriteLog@contesting.com
http://lists.contesting.com/mailman/listinfo/writelog
WriteLog on the web:  http://www.writelog.com/

<Prev in Thread] Current Thread [Next in Thread>