WriteLog
[Top] [All Lists]

[WriteLog] COM 5 CW keying problem

To: <writelog@contesting.com>
Subject: [WriteLog] COM 5 CW keying problem
From: "Ronald Lodewyck" <RLodewyck@csustan.edu>
Date: Sat, 19 Mar 2011 16:11:49 -0700
List-post: <writelog@contesting.com">mailto:writelog@contesting.com>
Help!
 
Having trouble getting new homebrew CW keying interface to work with Writelog.  
 
Problem:
No CW keying on COM 5 if COM6 = Rig = Elecraft K3.
Keys CW OK on COM5 DTR if No Rig is selected.
 
Details:
COM5 and COM6 are Edgeport/4 USB to Serial adapter.
DTR is keyed via an optoisolator.
DXLabs works perfectly with rig=K3 on COM 6 and CW keying on COM 5.
Writelog controls K3 AOK on COM6 whether CW port set to COM 5 or not.
If I set CW port to COM 5 and NO RIG selected, Writelog keys CW just fine.
But, if I then set COM 6 to Rig = Elecraft K3, transmit light comes on but no 
CW keying.
I changed to use a separate Prolific USB to Serial adapter for rig control on 
COM 3 and get same result:
 i.e. No CW keying on COM 5 if rig selected on COM3, CW keying on COM 5 works 
fine if I select NO RIG on COM 3 (or any other COM port).
All other control signals on COM 5 are left floating - they are not connected 
to anything.
 
I have used Writelog a long time, and built many CW keying circuits over the 
years and can't recall ever having a problem with any of them.  Is this a 
Writelog / USB-Serial issue?
 
Thanks for any help.
73,
Ron N6EE

_______________________________________________
WriteLog mailing list
WriteLog@contesting.com
http://lists.contesting.com/mailman/listinfo/writelog
WriteLog on the web:  http://www.writelog.com/