Jerry,
My PRO works on the default address 5Ch, you mentioned 052c but it may have
been a typo. The other settings on the PRO are
Baud Rate - Auto
Transceive - On
with IC-731 - Off
In WriteLog I have it set up on COM1 with the PRO selected as the radio
Baud Rate - Auto
Poll is checked
Comm PTT - No
I'm running WriteLog 10.24G.
Hope this helps. Good luck.
73,
Pat KØPC
At 03:08 PM 9/8/01 -0400, Jerry Flanders wrote:
>When I set the WL rig control port configuration to 756PRO, WL could not
>communicate with my new PRO, which was set to the default address 052c (?)
>
>I know the electronics is AOK, because if I lie and tell WL it is a 756
>and re-set the PRO to use the 756's address, WL can talk to the rig.
>
>Couldn't find anywhere in the ini file where the address is specified.
>Anybody know what address I am supposed to set the PRO to, or where I can
>set the address required by WL?
>
>Thanks
>
>Jerry W4UK
>