To do this, the close in guy anchor would have to be raised 14' high to
maintain the top guy's 50° angle.
John KK9A
Mike Ryan mryan001 wrote:
Consider making up the short distance by raising the short wire at its
termination point to offset the lack of overall distance. But be sure the
method of raising this short wire is substantial enough for the job. - Mike
>
>> On Thu, Dec 8, 2022, 3:27 PM dave arruzza via TowerTalk <
>> towertalk at contesting.com> wrote:
>>
>> I need to guy a Rohn 25 tower
>> 60' high
>> 2 sets of guys per Rohn manual
>> 1 set needs to be 36' not the standard 48' out from the tower
>> Comments please
>> 73Dave W1CTN
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com