Dave

Is this tower we discussed?

60 ft tower guyed at 25 and 50 for what you are planning. Also given your short 
guy point situation maybe consider 4 way guys instead of 3?  Can use short guy 
points with4. 

Regards,

Mark, K1RX


> On Dec 8, 2022, at 4:45 PM, Doug Christensen <auriga1usa@gmail.com> wrote:
> 
> It depends on the load. The EPA (extended profile area). Personally I would
> install 6 guy wires at a 35゚ angle from the tower. At 50',and. at 30'.
> 
> 73
> Doug, WB1E
> 
>> On Thu, Dec 8, 2022, 3:27 PM dave arruzza via TowerTalk <
>> towertalk@contesting.com> wrote:
>> 
>> I need to guy a Rohn 25 tower
>> 60' high
>> 2 sets of guys per Rohn manual
>> 1 set needs to be 36' not the standard 48' out from the tower
>> Comments please
>> 73Dave   W1CTN
>> _______________________________________________
>> 
>> 
>> 
>> _______________________________________________
>> TowerTalk mailing list
>> TowerTalk@contesting.com
>> http://lists.contesting.com/mailman/listinfo/towertalk
>> 
> _______________________________________________
> 
> 
> 
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
<Prev in Thread] Current Thread [Next in Thread>