To: | "[TowerTalk]" <towertalk@contesting.com> |
---|---|
Subject: | Re: [TowerTalk] Rohn anchor bolts, grade? |
From: | JVarney <jvarn359@gmail.com> |
Date: | Mon, 4 Apr 2022 09:29:54 -0700 |
List-post: | <mailto:towertalk@contesting.com> |
J-bolts are essentially obsolete. When the 2014 version of the ACI code came out, the design pullout strength of J-bolts were sharply reduced based on laboratory results that showed that concrete is crushed around the inner elbow of the J-shape. Headed bolts are preferred now. I would ask Rohn if they feel the J-bolts continue to meet the latest code standards and if they have a recommended headed bolt substitute. 73 Jim K6OK WW3S wrote: Yep, 1/2x12bb are the ones……grade 36 ? _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [TowerTalk] Rohn anchor bolts, grade?, maflukey |
---|---|
Next by Date: | [TowerTalk] Rohn anchor bolts, grade?, jim.thom jim.thom@telus.net |
Previous by Thread: | Re: [TowerTalk] Rohn anchor bolts, grade?, maflukey |
Next by Thread: | [TowerTalk] Rohn anchor bolts, grade?, jim.thom jim.thom@telus.net |
Indexes: | [Date] [Thread] [Top] [All Lists] |