On 12/31/2021 3:52 AM, Rob Atkinson wrote:
 
Why can't it be guyed to help stabilize it?   Even three ways at the
top with dacron or kevlar to some deep earth screws is better than
nothing, especially if you use cheap leg insulators.
 
Many ways to skin that cat. I have a 120 ft Rohn 25 guyed at 30, 60, 90, 
and 120 ft with about 4 ft in a poured concrete base. I also have an 
unguyed 35 ft Rohn 35 (the one private labeled for Motorola scaled up 
from 25) also with about 5 ft in a LOT of concrete. When the second one 
was installed, my climber advised me that it was stable enough without 
guys, so we opted not to guy it. I live in an area (NorCal) where we 
don't get more than about 75 mph winds. 
73, Jim K9YC
_______________________________________________