On 3/11/2021 1:13 PM, K9MA wrote: FWIW, I recall that 75 Ohms minimizes loss, while 50 Ohms maximizes power capacity. No doubt that was for a solid dielectric, and may be73, Scott K9MA For air dielectric, 77 ohms minimizes loss. For solid PE dielectric, the lowest loss occurs very close to 50 ohms. 73 Rick N6RK _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |