For cheap control wire, 18/2 speaker wire is pretty attractive. A lot of it is CCA but not of much consequence for control loads.

https://www.ebay.com/itm/Security-Wire-Burglar-Alarm-18-2-500FT-Stranded-Shielded-Control-Speaker-Cable/121761392647?hash=item1c598b6807:g:Wu0AAOSwKIpV-UlQ

Or burglar alarm 4 conductor, again CCA

https://www.ebay.com/itm/Security-Wire-Burglar-Alarm-18-4-500FT-Stranded-Shielded-Control-Speaker-Cable/122625414141?_trkparms=aid%3D1110006%26algo%3DHOMESPLICE.SIM%26ao%3D1%26asc%3D20131003132420%26meid%3Da4273a868eed4ebba6672a00681bf682%26pid%3D100005%26rk%3D3%26rkt%3D12%26mehot%3Dpf%26sd%3D121761392647%26itm%3D122625414141%26pmt%3D1%26noa%3D0%26pg%3D2047675%26algv%3DSimplAMLv5PairwiseWeb%26brand%3DLogico&_trksid=p2047675.c100005.m1851


Grant KZ1W


On 4/14/2020 04:20, Tyler Stewart via TowerTalk wrote:
I’m sure it would work for small relays.  You can always boost the voltage to compensate.  That said I 
wouldn’t use it for that unless it’s a very temporary installation.  get some small gauge 
Burial jacketed copper
Ty K3MM

Sent from AOL Mobile Mail
Get the new AOL app: mail.mobile.aol.com
  On Monday, April 13, 2020, tony.kaz--- via 
TowerTalk <towertalk@contesting.com> wrote:

Has anyone ever measured the resistance of WD-1A cable? If so it will save
the trouble of pulling some off a spool to test.

Also the plan would be to use to control 12V to relays at the feedpoints of
my 80M 4-Sq. The cable would be buried except for the vertical portion as
the feedpoints are elevated. Based on previous experience with WD-1A outside
I saw rusting of the wires. Is this wire typically only used for temporary
use or have folks had success with using something like liquid tape to seal
the ends where terminals were soldered?

My backup plan is to buy a 500' spool of Southwire Landscape wire 16/2
stranded copper.

73 and stay safe

N2TK, Tony

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
<Prev in Thread] Current Thread [Next in Thread>