I wud look at i think it is RG-393  that will carry im almost for sure your voltage, if it will work i can send that much  gratis  ..  border talk for free ...

mac/mc  w5mc


On 5/10/2019 11:55 AM, Steven Katz wrote:
The mil spec rating for RG-213/U is 3700Vrms max; this is 5232Vpk.

I wouldn't use it at 7.7kVdc.

-----Original Message-----
From: TowerTalk <towertalk-bounces@contesting.com> On Behalf Of Jim Thomson
Sent: Friday, May 10, 2019 9:52 AM
To: towertalk@contesting.com
Subject: [TowerTalk] RG-213 Hi Pot ?

Does anybody know how much max V is on  RG-213 ?   Like what are the results if 
a hi-pot tester used..
and say cranked up to the point where  just a few ma occurs .     I have an 
application where I need a  HV
cable, less than 10 ft, that will  easily handle 5700 /  7700  vdc.   It will 
be hardwired at both ends, no HV connectors.
And with braid peeled way back from the center conductor, like  2-4 inches .
The plan was to also wrap some red electrical tape  every few inches  along its 
 entire  length, to readily identify it as a HV cable.

Tnx....  JIm   VE7RF
_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
<Prev in Thread] Current Thread [Next in Thread>